TriPanel® between joists underfloor heating
Our between-joists system, for a flexible underfloor heating solution with zero height build-up.

Why choose TriPanel® between joists?
TriPanel® is a between-joists system designed for seamless integration into suspended timber floors with no height build-up and a dry, quick installation.
Compatible with both new and existing joists, standard chipboard and engineered board floor decks, TriPanel® between joists is a flexible solution for a wide range of installation scenarios.
Each TriPanel® system is meticulously designed to suit your project, ensuring optimal performance and simple installation. Our expert design team carefully calculate room-by-room heat losses to optimise pipe layouts and flow rates for maximum efficiency.
Works with new and existing joists
Zero Height build up
For suspended timber
Lightweight
Dry install
Fast response time
Get a bespoke quote
We would love to speak with you to discuss your project – upload your plans for a free quote.
Installing TriPanel® between joists
TriPanel® has been developed for dry, quick installation between timber battens or joists.
Step 1. Prepare the joists by creating notches for pipe to pass between bays, insulating with mineral wool and fitting battens in preparation for the plywood platforms.
Step 2. Fit the plywood platforms to the battens leaving a 25mm gap for the polystyrene TriPanel®.
Step 3. With the TriPanels cut to size according to chosen pipe spacings, fit the panels along each joist bay, starting at the end of the notch.
Step 4. Fit the heat diffuser plates into the tracked TriPanels leaving a small gap between plates and stopping just shy of the pipe turns.
Step 5. Starting from the room furthest from the manifold, lay the pipe following your bespoke design drawings. Continue until there is just enough tube remaining to return to the manifold.
Step 6. Once the correct lengths of tube are laid, trim excess coil length and connect to the manifold as described in your Nu-Heat Installation Manual. You can then fill and pressure test the system before fitting the moisture resistant chipboard.
Not sure TriPanel® between joists is the one? We’ll help you find the right system.
Call us on 01404 549770 to speak to a specialist, or use the underfloor heating selector tool to explore more of our products.
It was an absolute no-brainer to go for Nu-Heat underfloor heating in our own home.
Ann and Wyndham Collins
TriPanel® between joists performance with different floor coverings
Different floor covering materials will affect the way an underfloor heating system heats a room and may also be sensitive to heat.
Available heat flow (W/m2) | ||||
Flow temperature | 40°C | 45°C | 50°C | 55°C |
Vinyl (*limit to 75W/m2) | 42 | 54 | 69 | 82 |
---|---|---|---|---|
Natural stone/tiles (*limit to 100W/m2) | 42 | 54 | 69 | 82 |
14mm engineered board | 39 | 52 | 65 | 78 |
2 tog carpet/underlay | 35 | 46 | 58 | 70 |
*We factor this into the design of your system. |